Cablage Volet Roulant Repack Here
| Problem | Probable cause | Solution | |---------|----------------|----------| | Motor runs only one direction | One control wire disconnected or limit switch tripped | Check continuity of black/grey wire; reset limits | | Shutter stops before end | Mechanical limit incorrectly set | Readjust limit screws | | Motor hums but no movement | Phase and neutral reversed on motor terminals | Swap L and N on motor side (check wiring diagram) | | Both directions work but shutter descends on “up” | UP/DOWN wires swapped | Invert black and grey wires at switch or motor |
Avant de commencer, il est important de connaître les composants du système de cablage d'un volet roulant : cablage volet roulant
Never connect UP and DOWN simultaneously – the switch mechanically prevents this. | Problem | Probable cause | Solution |
| Component | Description | |-----------|-------------| | Tubular motor | Single-phase induction motor (230V AC typically) with built-in thermal protection and limit switches | | Control point | 2 or 3-position switch (monte / arrêt / descend) | | Wiring | 5-conductor cable (phase, neutral, up, down, earth) or 4-conductor if no earth | pour les plus bricoleurs
De plus, pour les plus bricoleurs, il existe aujourd'hui des . Ces kits incluent le moteur, les supports, l'axe et parfois même les câbles pré-connectés, rendant le "cablage volet roulant" accessible même aux novices.